Crestchic: Costs incurred by major datacentre power outages continue to rise

Market research from the Uptime Institute shows a year on year increase in the cost and frequency of downtime in data centres, with one in six operators estimating the total cost incurred by their most recent downtime event as more than $1m. With power problems identified as the biggest cause of major outages, Paul Brickman from Crestchic Loadbanks explores whether the data centre market needs to invest more in the resiliency of back-up power.

As the world’s reliance on digital infrastructure increases, the cost and impact of data centre outages are becoming more pronounced. The role of data centres in supporting mission-critical business, economic and social activities means that the ability to operate, secure and recover systems quickly and efficiently is critical to the global economy.

Data centre outages: Frequent, damaging and expensive  

As an advisory organisation focused on improving the performance, efficiency, and reliability of data centres, the Uptime Institute carries out regular market research, gathering unique insights from the industry. Data from the last three years suggests that bigger outages are occurring with disturbing frequency, as well as becoming more damaging and expensive.

Yet, while the industry’s focus on efficiency and reliability means that preparedness is in the data centre industry’s DNA, the figures tell a surprising story.  Three-quarters of respondents admit that their most recent major outage was preventable and that power failure — which impacts everything on-site and can cause knock-on effects — is the most likely cause of major outages.

Back-up power resilience

As a business, our perception from working in the industry is that most data centres have robust strategies in place to deal with power blackouts. Most are already wise to the importance of testing power supplies to avoid downtime, with both generators and Uninterruptible Power Systems (UPS) universally accepted as a piece of critical business infrastructure. Generally speaking, problems arise when operators fail to regularly or adequately test and maintain their back up power systems.

The reality is, in many instances, that those in charge of maintaining backup power have no regular testing schedule, making an assumption that occasionally powering the generator up, or testing for a minimal period, will suffice. When power is mission-critical, as it is in a data centre environment, testing back-up power systems can make all the difference to whether they operate effectively when called upon. Load banks should be used to test, support, or protect a critical backup power source and ensure that it is working optimally should an outage occur.

Testing data centre power: the role of load banks

As the most recent report from the Uptime Institute clearly states: “The impact of a power outage is wide and deep, and the knock-on effects can be long-lasting – even if the initial failure is quickly fixed.”  To avoid this eventually, all generators should be tested at least annually for real-world emergency conditions using a resistive-reactive 0.8pf load bank. As well as ensuring that the generator works efficiently under real operational conditions, the testing will also show how a system will cope with a voltage drop in its regulator. This is particularly important for data centres, where multiple generators might be operated in parallel. In this type of application, a problem with one generator could prevent other generators from working as they should. In addition to testing back-up power, load banks can also be used to heat load test the output of data centre servers, which exude enormous amounts of heat.

Properly planned and implemented, preventative maintenance strategies can minimise the likelihood of unscheduled breakdowns and outages, effectively negating the potential risk of costly commercial, reputational and legal issues.

For more information on Crestchic’s load banks, the need for testing of critical power supplies and advice on the various load bank options available, visit www.crestchicloadbanks.com 

Northbridge Industrial Services (LON:NBI) has two core activities, Crestchic Loadbanks and Tasman Oil Tools. Crestchic is a specialist electrical equipment business which manufactures, sells and rents loadbanks and transformers from its base in Burton on Trent and has depots in France, Germany, Belgium, UAE and Singapore. Crestchic also has satellite locations in China and the USA.

Click to view all articles for the EPIC:
Or click to view the full company profile:
Facebook
Twitter
LinkedIn
Northbridge Industrial Services Plc

More articles like this

Northbridge Industrial Services Plc

What is generator loadbank testing?

In a normal setup, a UPS (uninterruptible power supply) is found between alternative sources of power and the protected loads. The reason behind this is to protect the loads from unexpected power failures which could damage the loads.

Northbridge Industrial Services Plc

Why use a loadbank?

Over time, lightly loaded generator sets develop wet-stacking and carbon build-up in the combustion chambers and exhaust system. The use of a loadbank helps prevent this and determines the generator’s capability to produce maximum output in

Northbridge Industrial Services Plc

Northbridge Industrial Services upgrades outlook

Burton on Trent-based Northbridge Industrial Services has increased its outlook for the current financial year as the business prepares to change its name. The listed company, which provides industrial equipment to the construction, power and oil

Northbridge Industrial Services Plc

Is load bank testing necessary for containerised data centres?

Load bank testing: With an ever-expanding remit of applications, containerised, or mobile, data centres are rapidly becoming the go to solution for meeting today’s dynamic, high volume data processing and communications demands. But is the temporary

Northbridge Industrial Services Plc

Crestchic at DataCentreWorld 2022 in Frankfurt

Crestchic is delighted with the results from DataCentreWorld, which was held on the 11th and 12 May in Frankfurt. Team members were on hand to answer questions from the many attendees over the two days. Chris

Northbridge Industrial Services Plc

Load banks at container ports

The container shipping industry is an ever-growing, fast-paced environment, and power infrastructure cannot always grow in-line with power requirements. For this reason, many container ports are choosing to expand their power capacity by using stand-alone temporary

Northbridge Industrial Services Plc

Load banks in the healthcare sector

Testing solutions from the world’s leading load bank manufacturerLoad banks are used to test the effectiveness of standby systems in a variety of situations: Key Factors Running a generator on full load helps to avoid “wet

Northbridge Industrial Services Plc

Load banks in the marine & shipbuilding sector

The need for reliable back-up power in the marine environment is paramount. A loss of navigation or steering can be catastrophic. A back-up power supply that is proven to be 100% effective, first time, every time,

Northbridge Industrial Services Plc

Load banks in the data centre sector

In today’s fast-moving world, we have all become accustomed to instant online access. We do our banking, renew our home insurance and book hospital appointments online. We don’t even print photos anymore, we store them online

Northbridge Industrial Services Plc

Northbridge Industrial group revenue up 20% to £29.5 million

Northbridge Industrial Services plc (LON:NBI), the power reliability company, has announced its audited results for the year ended 31 December 2021, which are in line with increased market expectations. Highlights: ·  Group revenue from continuing operations up

Northbridge Industrial Services Plc

Loadbanks & Transformers for shipyards

Crestchic loadbanks are widely used for the testing of Gensets – Gas Turbines – UPS & DC systems.Crestchic’s loadbanks and transformers are popular with shipyards around the world, with over 30 years’experience gained from supplying rental

Northbridge Industrial Services Plc

Common reasons for generator failure (and how to avoid them)

With society increasingly reliant on electricity, interruptions in power supplies have the potential to cause chaos, impacting everything from our home lives to travel, business productivity to data integrity and, in more extreme cases, loss of